High Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester Lab Test

Type : Testing Machine

Accuracy Class : High Accuracy

Accuracy : ----

Brand Name : LONROY

Place of Origin : Guangdong, China

Application : Auto Testing, Laboratory Testing, Lab Testing

customized support : OEM, ODM, OBM

power : ---

Protection Class : Ip56

Voltage : 220V Electrical Equipment

warranty : 1 Year

Optimal Flow Rate : (0.7~1.2) L/min

Inlet Pressure : (2~50) kPa

Signal Output : RS-485/RS-232, (4-20) mA

Power Supply : 100~240VAC, 300W (maximum heating power)/100W (stable power)

MOQ : 1

Contact Now

High Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester Lab Test

High Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester

Product Description

Product Introduction

The greenhouse gas (CO2/CH4/N2O) emission analyzer utilizes proprietary microfluidic infrared gas sensing technology (international invention patent PCT/CN2018100767), enabling simultaneous and accurate measurement of CO2, CH4, N2O, and CO gas concentrations in flue gas. The measurement range can be as low as 200 ppm, with an accuracy of up to 1% F.S., and features strong resistance to gas cross-interference and lower drift.

For high-concentration CO2 and medium-to-high range CO measurement needs, the analyzer can be flexibly configured with sensor modules using the company's proprietary non-dispersive infrared (NDIR) gas sensor technology, offering good stability, small size, and low cost.

Product Features

Simultaneous and continuous measurement of up to five gases: CO2, CH4, N2O, CO, and O2

CO2, CH4, N2O, and CO measurements can utilize microfluidic infrared patented technology, with a range as low as 200 ppm and accuracy up to 1% F.S.

Low drift, strong resistance to moisture interference, and good long-term stability

For medium-to-high concentration measurement needs, dual-beam infrared sensing technology can be used to measure CO2 and CO, allowing for flexible configuration.

Features both digital and analog signal output for easy data management.

Application Areas

Greenhouse gas monitoring in key emission industries such as thermal power plants, steel, cement, oil and gas extraction, coal mining, and exhaust gas pollutant treatment.

PHigh Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester

Technical Specification

Measured Components

CO2,CH4,N2O,CO,O2

Measurement Principle

Micro-flow infrared sensing technology (Micro-flow NDIR): CO2/CH4/N2O/CO

Dual beam infrared sensing technology (Dual beam NDIR): CO2 (high range) and CO (medium-high range)

Electrochemical sensing technology (ECD): O2

Measurement Range

Carbon dioxide (CO2)

Microflow: Measurement range 0-500 ppm, resolution 1 ppm

Microflow: Measurement range 0-20%, resolution 0.01%

Dual beam: Measurement range 0-25/100%, resolution 0.01%

Measurement Range

Methane (CH4): Measurement range 0-1000 ppm, resolution 1 ppm

Nitrous oxide (N2O): Measurement range 0-1000 ppm, resolution 1 ppm

Measurement Range

Carbon monoxide (CO)

Microflow: Measuring range 0-200/5000 ppm, resolution 1 ppm

Dual beam: Measuring range 0-1/5%, resolution 0.001%

Measurement Range

Oxygen (O2)

Measuring range 0-25%, resolution 0.01%

Measurement Accuracy

Microfluidic infrared measurement of CO2/CH4/N2O/CO: ±1% F.S.

Dual-beam measurement of CO2/CO: ±2% F.S.

Electrochemical measurement of O2: ±2% F.S.

Repeatability

≤±1%

Response Time

T90 < 25s

Optimal Flow Rate

(0.7~1.2) L/min

Inlet Pressure

(2~50) kPa

Sample Gas Requirements

Water removal (no condensation); dust filtration (filtration accuracy < 1μm)

Signal Output

RS-485/RS-232, (4-20) mA

Power Supply

100~240VAC, 300W (maximum heating power)/100W (stable power)

Diagnostic Functions

Equipped with self-diagnostic function to check sensor status

High Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester Lab TestHigh Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester Lab TestHigh Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester Lab TestHigh Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester Lab Test


Product Tags:

Greenhouse gas emission analyzer lab tester

      

Flue gas CO concentration analyzer

      

Laboratory CO2 CH4 N2O tester

      
Quality High Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester Lab Test wholesale

High Precision Greenhouse Gas (CO2/CH4/N2O) Emission Analyzer Laboratory Flue Gas CO Gas Concentrations Tester Lab Test Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: DONGGUAN LONROY EQUIPMENT CO LTD
*Subject:
*Message:
Characters Remaining: (0/3000)